Request DemoContact Us
Qualityze LogoQualityze Symbol
HomeProductsIndustriesServicesComplianceBlogsCompany
Request DemoSupport

Corporate Headquarters

Qualityze Inc.
3903 Northdale Blvd Suite 100E
Tampa – FL 33624 USA

Contact Sales: +1-813-451-9913

Phone: +1-877-207-8616

Email: info@qualityze.com

UK Regional Office

Qualityze Inc.
450 Bath Road, Longford
Heathrow, London- UB70EB

Email: info@qualityze.com

India Regional Office

Qualityze Solutions Pvt Ltd.
No. 27, 1st floor, 80 ft. road, KHB Colony, 2nd stage, Basaveshwaranagar,
Bangalore 560079 INDIA

Phone: +91 96117 58187

Email: info@qualityze.com

Qualityze Inc.

About usDownloadsBlogsCareersPrivacy Policy
HomeNewsBlogsDownloads

Products

All Qualityze ProductsNonconformance ManagementCAPA ManagementDocument ManagementChange ManagementTraining ManagementAudit ManagementSupplier Quality ManagementComplaints ManagementCalibration ManagementMaintenance ManagementInspection ManagementPermit ManagementMaterial Compliance ManagementForms ManagementField Safety & Recall ManagementAdverse Events ManagementIncident ManagementRisk ManagementBatch Records Management8D Process

Industries

LifesciencesFood & BeveragesHealthcareManufacturingMedical DevicesPharmaceuticalsBiologicsBiotechnologyNutraceuticalsCannabisCompounded DrugsBlood & TissueAutomotiveAerospace & DefenseElectric VehiclePlastic and RubberElectronics and AppliancesChemical & AgrochemicalOil & GasEnergy & UtilitiesMetals & Mining

Services

Salesforce Consulting ServicesImplementation ServicesValidation Services

Compliance

ComplianceISO 9001ISO 1348521 CFR 82021 CFR Part 11AS 9100IATF 16949

Company

About usWhy usPartnersPlatform OverviewWhy CloudClient TestimonialsQMS SecurityContact UsCustomer SupportCareersDownloadsBlogsNewsVideosPrivacy PolicyGDPR Compliance
© 2025 Qualityze | All rights reserved. | Privacy Policy
All Posts

What Is IEC 62304: It’s Important in Med Device Compliance

Medical DevicesCAPA ManagementEQMS
Qualityze
27 Jun 2025

Table of Content


1 What is IEC 62304?

2 IEC 62304 Software Classifications

3 Who Must Comply with IEC 62304?

4 IEC 62304 Checklist

5 Key Requirements of IEC 62304

6 Steps to Meet IEC 62304 in Your Medical Device Project

7 Why Every Medical Device Company Should Understand IEC 62304

8 How Medical Device Companies Can Ensure IEC 62304 Compliance

9 Simplify IEC 62304 Compliance with Qualityze EQMS

10 Conclusion

What Is IEC 62304: It’s Important in Med Device Compliance

IEC 62304 is an international standard that defines the life cycle requirements for medical device software. It provides a framework for developing and maintaining software used in medical devices, ensuring safety and effectiveness throughout the software’s life cycle. This standard is recognized by regulatory bodies such as the U.S. Food and Drug Administration (FDA) and the European Union’s Medical Device Regulation (MDR), making compliance essential for market approval in these regions. 

What is IEC 62304?

IEC 62304 is an international standard that specifies lifecycle requirements for medical device software, including software development, maintenance, and risk management. The standard helps ensure software safety and effectiveness and provides a framework for building reliable software.

  • Software Development: It includes planning, design, implementation, and testing. 
  • Software Maintenance: Covers activities after release, like updates and bug fixes. 
  • Risk Management: Identifies and mitigates potential software risks. 
  • Problem Resolution: Outlines how to handle software issues. 
  • Configuration Management: Manages changes to the software. 

IEC 62304 Software Classifications

IEC 62304 classifies medical device software based on its potential to cause harm. The classification dictates the rigor of the development process, and higher classifications require more stringent controls. 

Classification  Description 
Class A  No injury or damage to health is possible. Software typically manages minor functions or provides information without direct patient impact. 
Class B  Non-serious injury is possible. Software performs functions where failure could lead to minor harm or inconvenience, but not life-threatening situations. 
Class C  Death or serious injury is possible. Software controls critical functions where failure could result in severe harm, permanent impairment, or death. This class demands the highest level of scrutiny and control. 

Who Must Comply with IEC 62304?

Manufacturers and developers of medical device software must comply with IEC 62304. This includes a broad range of entities. Compliance ensures their software meets safety and performance standards. 

Entity  Description 
Medical Device Manufacturers  Any company that develops, produces, or markets medical devices containing software. This includes both hardware and standalone software. 
Software Developers for Medical Devices  Companies or individuals specifically creating software components for integration into medical devices. This can include operating systems, application software, or embedded software. 
Companies Developing Standalone Medical Software  Applications such as mobile medical apps, health information systems, or diagnostic software that operates independently of a physical medical device but still falls under medical device regulations. 
Original Equipment Manufacturers (OEMs)  Companies that provide software components or modules to other medical device manufacturers. They must ensure their supplied software meets the standard’s requirements. 
Contract Research Organizations (CROs)  If CROs are involved in developing or testing software for medical devices as part of their services, they need to be aware of and adhere to IEC 62304 principles. 

IEC 62304 Checklist

A comprehensive checklist helps ensure compliance with IEC 62304. This list guides development teams through the necessary steps. It covers various aspects of the software lifecycle. 

  • Software Development Plan: Have a detailed plan. 
  • Software Requirements Specification: Define all software requirements clearly. 
  • Software Architecture Design: Design the software structure. 
  • Software Design Specification: Document the detailed design. 
  • Software Unit Implementation and Verification: Code and test individual software units. 
  • Software Integration and Integration Testing: Combine units and test their interaction. 
  • Software System Testing: Test the complete software system. 
  • Software Release: Prepare for software release. 
  • Software Risk Management File: Maintain a file documenting risks and mitigations. 
  • Problem Resolution Process: Establish a process for handling software issues. 
  • Configuration Management Plan: Plan for managing software changes. 
  • Software Maintenance Plan: Plan for ongoing software maintenance. 

Key Requirements of IEC 62304

IEC 62304 outlines specific requirements across the software lifecycle. These requirements ensure a systematic and controlled approach and adhering to them is crucial for compliance. 

  • Software Development Planning: Plan all development activities. 
  • Software Requirements Analysis: Define all software requirements. 
  • Software Design: Design the software system. 
  • Software Implementation: Code the software according to design. 
  • Software Verification: Test the software to ensure it meets requirements. 
  • Software Release: Control the release process. 
  • Software Problem Resolution: Manage and resolve software issues. 
  • Software Configuration Management: Control software changes. 
  • Software Maintenance: Maintain the software throughout its lifecycle. 
  • Software Risk Management: Identify and mitigate software risks. 

Steps to Meet IEC 62304 in Your Medical Device Project

Meeting IEC 62304 requires a structured approach. Integrating the standard’s principles early saves time and effort. Follow these steps for successful compliance. 

  • Determine Software Safety Class: Classify your software (A, B, or C). Classifying your software drives the rigor of your process. 
  • Establish a Quality Management System (QMS): Implementing robust Quality Management System is fundamental for medical device development. 
  • Develop a Software Development Plan: Create a detailed plan. It outlines all lifecycle activities. 
  • Define Software Requirements: Document precise, unambiguous software requirements. 
  • Design the Software Architecture: Create a well-defined software architecture. 
  • Implement and Verify Software Units: Code and test individual software components. 
  • Integrate and Test Software: Combine components and perform integration testing. 
  • Perform System Testing: Conduct comprehensive testing of the entire software system. 
  • Manage Software Risks: Continuously identify, analyze, and mitigate software risks. 
  • Establish a Problem Resolution Process: Define how to address software issues. 
  • Implement Configuration Management: Control changes to software and documentation. 
  • Plan for Software Maintenance: Develop a plan for post-market software activities. 
  • Maintain Traceability: Link requirements to design, code, and tests. 
  • Document Everything: Keep detailed records of all development activities. 

Why Every Medical Device Company Should Understand IEC 62304

Understanding IEC 62304 is not just about compliance. It is a strategic imperative for medical device companies. This knowledge helps build better products and grow your business. 

  • Ensures Patient Safety: It provides a framework for developing safe software. Patient well-being is paramount. 
  • Facilitates Regulatory Approval: Regulatory bodies worldwide, including the FDA in the US and notified bodies in the EU, expect compliance. It simplifies market access.  
  • Reduces Product Recalls: A robust development process minimizes defects and lowers the chance of costly recalls. 
  • Improves Software Quality: The standard promotes best practices in software engineering, leading to higher-quality software. 
  • Enhances Market Competitiveness: Compliant products are more trustworthy, giving a competitive edge. 
  • Manages Development Risks: It helps identify and mitigate risks early, saving time and resources. 
  • Fosters a Culture of Quality: Adhering to the standard embeds quality into your processes. 
  • Avoids Legal Issues: Non-compliance can lead to significant legal penalties and liabilities. 

How Medical Device Companies Can Ensure IEC 62304 Compliance

Achieving and maintaining IEC 62304 compliance requires ongoing effort. Companies need to implement robust processes and tools. 

  • Implement a Robust Quality Management System (QMS): A QMS provides the overarching framework. It integrates all compliance activities. 
  • Train Your Team: Ensure all personnel understand IEC 62304 requirements. Regular training is essential. 
  • Use Appropriate Tools: Employ specialized software development and lifecycle management tools. These streamline compliance efforts. 
  • Conduct Regular Audits: Perform internal audits to check for compliance gaps. Address findings promptly. 
  • Seek Expert Guidance: Consider consulting with specialists in medical device software compliance. 
  • Maintain Comprehensive Documentation: Keep detailed records of every development phase. Commitment to maintaining detailed records demonstrates compliance. 
  • Implement Traceability: Link requirements to design, code, and test cases. This shows adherence. 
  • Conduct Thorough Testing: Rigorous testing is critical. It validates software performance and safety. 
  • Establish a Strong Risk Management Process: Continuously identify and manage software risks. 
  • Embrace Agile but Documented Development: Use Agile methods, but ensure proper documentation. 

Simplify IEC 62304 Compliance with Qualityze EQMS

Meeting IEC 62304 requirements can be complex. Qualityze EQMS offers a streamlined solution. It helps medical device companies manage quality processes efficiently. It integrates various functions, covering document control, risk management, and training.  

Qualityze EQMS simplifies compliance by providing a centralized platform. It helps automate tasks and reduces manual errors, ensuring consistency across all processes and improving traceability. You can track requirements, designs, and test cases. It also manages non-conformances and corrective actions, ensuring a closed-loop quality system. Qualityze helps companies maintain a compliant posture. It provides the tools for robust software development and maintenance.

Conclusion

IEC 62304 is a foundational standard for safe medical device software. It guides manufacturers through the entire software lifecycle, including development, maintenance, and risk management. Adhering to its principles ensures patient safety and streamlines regulatory approvals. Companies gain a competitive advantage by building high-quality software.  

Understanding its classifications and requirements is vital. Implementing a robust quality management system and using appropriate tools helps achieve compliance. IEC 62304 compliance protects patients and promotes innovation in medical technology. It ensures the software powering life-saving devices is reliable and effective.

Share